Pipe sleeve thru floor slab or wall.
Piping roof support detail.
Single pipe curb assembly detail.
During the coronavirus pandemic the pate company has continued normal manufacturing sales shipping receiving and administrative operations.
55 red flag 7 hangers.
A pipe support used to support roof mounted gas pipes electrical conduit solar piping and other mechanical piping.
Single 3 way water coil piping detail with 3 way control valve.
Featuring a similar design to the time tested model 1 5 the model 3 0 is just as simple to install and is guaranteed to withstand harsh rooftop conditions for years to come.
Roof conduit support detail.
Pipe supports are designed to anchor guide absorb shock and support a specified load.
Top of riser detail 51 ins e r t d e ta i l h e r e.
Pipes rest in a u shaped cradle situated in a polycarbonate resin seat.
Unique design absorbs thermal expansion and contraction of pipes thus preventing damage to the roof membrane.
Pate offers roof products custom curbs metal building roof curbs equipment support rails pipe supports skylights smoke vents and isolation bases.
Coordinate trench detail with architectural structural.
4 100mm 5 4 center bolt for span greater than 24 600mm 7 8 22mm high density insert typical cold pipe type 40 shield banded to pipe.
Package dircet drive propeeler type wall mounted fan.
Refrigeration pipe hanger detail 52.
Riser support detail 53.
When used in combination with b line series strut systems or pipe hanger systems dura blok supports offer a total solution for rooftop applications such as solar pv mounting systems piping hvac equipment roof top walkway ducts conduit and cable tray supports.
Floor slab penetration detail.
Provide pipe supports per detail on sheet.
The 3 0 is fully compatible with the 3 r spacer as well as pipe guides and our 12 x12 support pad.
Non canted equipment roof support detail.
Support anchor for pipe risers.
Products in this category are used in the supporting of pipe for typical commercial industrial and fire protection applications.
Roof penetrations.
Detail for supporting pipe on roof.
Pipe trench in building nts notes.
Piping serving the tower.
Install piping to permit complete maintenance access to the tower.
Locate the thermostat as shown on the plans with a sun shield and set it to energize the heat tape atan outdoor temperature below 45 deg.
Piping penetration at wall.
Conduit roof penetration detail.
Refer to specification sealing caulking.
Condenser pipe support detail 54.
Single line ahu control diagram ahu.
Top of riser detail approved pipe hanger w installation adhered.
Made of 100 recycled rubber the dura blok support has no sharp or abrasive edges and does not penetrate the roof helping extend the life of the roof.
57 walk in coolers freezers.
56 walk in boxes we all have at least one.